Esgotado

C102-10 6~24kV Stress Control Heat Shrink Tube

C102-10
$0.00
Introduction Stress control heat shrink tube.Electrical stress control protection of power cable termination and joint under 6~24kV. Features Operating temperature: -55 to 105°C Minimum fully recovery temperature: 125°C...
Tag:
Introduction
Stress control heat shrink tube.Electrical stress control protection of power cable termination and joint under 6~24kV.

Features
Operating temperature: -55 to 105°C
Minimum fully recovery temperature: 125°C
Voltage class: 6kV ~ 24kV
Effective electrical stress control
Single or Dual wall optional
Shrink ratio: 2.5:1
Standard Color: Black
Dimension
Part No.
C102-10
As supplied(mm)
Inner diameter
    D(min.)
After recovered(mm) Standard length
    (m/pc)
Inner diameter
   d(max.)
Wallthickness
t(nom.)
26-10 26  10  2.6  1.0~1.5
30-12 30  12  2.7  1.0~1.5
35/14 35  14  2.8  1.0~1.5
40/16 40  16  3.0  1.0~1.5
47/18 47  18  3.0  1.0~1.5
55/21 55  21  3.0  1.0~1.5
65/24 65  24  3.0  1.0~1.5
85/30 85  30  3.2  1.0~1.5
95/45 95  45  3.0  1.0~1.5

 

Technical Data

Property Test Method Requirement
Tensile Strength ASTM D2671 ≥12 MPa
Ultimate Elongation ASTM D2671 ≥300%
Heat Aging(136°℃/168h) ASTM D2671
Tensile Strength ≥10 MPa
Ultimate Elongation ≥250%
Water absorption(23°℃/24h) ASTM D2671 ≤0.5%
Low-temperature flexibility(-40°℃/4h) ASTM D2671 No cracking
Heat shock(200°℃/4h) ASTM D2671 No splitting
Volume resistivity ASTM D2671 ≥1×10#¹Ω.cm
Dielectric constant IEC 62631-2-1 10~25
Loss factor(50Hz) IEC62631-2-1 ≤1.0(1000V)

You have successfully subscribed!