Sold out
S6 Fluid resistant elastomer polyester heat shrink tube
$0.00
Introduction Specially formulated for optimum high temperature fluid resistance, and long term heat resistance. Flame retardant, very flexible. Resistant to aviation and diesel fuels, hydraulic fluids and lubricating...
Introduction
Specially formulated for optimum high temperature fluid resistance, and long term heat resistance. Flame retardant, very flexible. Resistant to aviation and diesel fuels, hydraulic fluids and lubricating oils. Particularly suitable as a jacketing material for military ground vehicle cables and harnesses.
Features
Operating temperature: -75 to 150°C
Minimum full recovery temperature: 150°C
Shrink ratio: 2:1
Flame-retardant, very flexible
Standard Color: Black(-0)
Compliant Standard AMS-DTL-23053/16
Dimensions
| Part No. S6/S6-TW |
As supplied(mm) | After recovered(mm) | Unit weight (max.) g/m |
Standard Length (m) |
|
| Inner diameter D(min.) |
Inner diamete d(max.) |
r Wall thickness t |
|||
| Normal S6 | |||||
| 1.6/0.85 | 1.6 | 0.85 | 0.40±0.08 | 3.1 | 200 |
| 2.4/1.2 | 2.4 | 1.2 | 0.51±0.08 | 5.9 | 200 |
| 3.2/1.6 | 3.2 | 1.6 | 0.76±0.15 | 9.6 | 200 |
| 4.8/2.4 | 4.8 | 2.4 | 0.84±0.15 | 14.7 | 200 |
| 6.4/3.2 | 6.4 | 3.2 | 0.89±0.15 | 19.3 | 200 |
| 9.5/4.8 | 9.5 | 4.8 | 1.02±0.20 | 31.5 | 122 |
| 12.7/6.4 | 12.7 | 6.4 | 1.22±0.20 | 42.5 | 122 |
| 15.9/7.9 | 15.9 | 7.9 | 1.32±0.28 | 57.5 | 61 |
| 19.1/9.5 | 19.1 | 9.5 | 1.45±0.28 | 80.1 | 61 |
| 22.2/11.1 | 22.2 | 11.1 | 1.55±0.28 | 98.5 | 61 |
| 25.4/12.7 | 25.4 | 12.7 | 1.78±0.28 | 120.0 | 61 |
| 31.8/15.9 | 31.8 | 15.9 | 2.20±0.41 | 172.5 | 30.4 |
| 38.1/19.1 | 38.1 | 19.1 | 2.41±0.41 | 243.0 | 30.4 |
| 50.8/25.4 | 50.8 | 25.4 | 2.79±0.41 | 342.0 | 30.4 |
| S6-TW(thinner wall) | |||||
| 1.6/0.85 | 1.6 | 0.85 | 0.40±0.08 | 3.1 | 200 |
| 2.4/1.2 | 2.4 | 1.2 | 0.51±0.08 | 5.9 | 200 |
| 3.2/1.6 | 3.2 | 1.6 | 0.51±0.08 | 7.0 | 200 |
| 4.8/2.4 | 4.8 | 2.4 | 0.51±0.08 | 9.6 | 200 |
| 6.4/3.2 | 6.4 | 3.2 | 0.64±0.08 | 15.6 | 200 |
| 9.5/4.8 | 9.5 | 4.8 | 0.64±0.08 | 22.2 | 122 |
| 12.7/6.4 | 12.7 | 6.4 | 0.64±0.08 | 27.0 | 122 |
| 15.9/7.9 | 15.9 | 7.9 | 0.76±0.15 | 37.6 | 61 |
| 19.1/9.5 | 19.1 | 9.5 | 0.76±0.15 | 47.2 | 61 |
| 22.2/11.1 | 22.2 | 11.1 | 0.89±0.15 | 60.2 | 61 |
| 25.4/12.7 | 25.4 | 12.7 | 0.89±0.15 | 67.6 | 61 |
| 31.8/15.9 | 31.8 | 15.9 | 1.02±0.20 | 90.4 | 30.4 |
| 38.1/19.1 | 38.1 | 19.1 | 1.02±0.20 | 115.4 | 30.4 |
| 50.8/25.4 | 50.8 | 25.4 | 1.14±0.20 | 157.9 | 30.4 |
Technical Data(GJB7274-2011)
| Property | Test Method | Requirement |
| Density | ASTM D792 | ≤1.50g/cm³ |
| Longitudinal change | 一 | -10%~10% |
| Restricted Shrinkage | 200°℃/30min | No cracking |
| Water absorption | 23°C/24h | ≤2.0% |
| Tensile Strength | 500mm/min | ≥11.7MPa |
| Ultimate Elongation | 500mm/min | ≥250% |
| Heat shock | 200°℃/4h | No cracking,dripping or flowing |
| Heat Aging | 150℃/168h | |
| Tensile Strength | ≥10.4MPa | |
| Ultimate Elongation | ≥200% | |
| Dielectric strength | 一 | ≥11.9kV/mm |
| Dielectric withstand | AC 2500V,60s | No breakdown |
| Volume resistivity | 一 | ≥1.0×10⁹ Ω ·cm |
| Fluid resistance | 23°C/24h | |
| Tensile Strength | ≥10.4MPa | |
| Utimate Elongation | ≥200% | |
| Dielectric strength | ≥7.9kV/mm | |
| Flammability | 一 | 60 second maximum burning duration |
| Copper corrosion | 135℃/16h | No Corrosion |
| Low-temperature flexibility | -55℃/4h | No Cracking |
| Thermal cycling | -55°℃/120°℃ | |
| Tensile Strength | /10 cycles | ≥10.4MPa |
| Ultimate Elongation | ≥200% | |
| Salt spray test | GJB150.11 | |
| Tensile Strength | ≥10.4MPa | |
| Ultimate Elongation | ≥200% | |
| Damp-heat test | GJB150.9 | |
| Tensile Strength | ≥10.4MPa | |
| Ultimate Elongation | ≥200% | |
| Fungus Resistance | GJB 150.10 | Not worse than rating 1 |