Ausverkauft

S17 Electromagnetic Shielding Protection Heat Shrink Tube

S17
$0.00
S17 Electromagnetic Shielding Protection Heat Shrink Tube Introduction Designed for shielding and protecting electromagnetic signal interference sensitive components in military equipment. Features Operating temperature: -55 to 135°C Minimum...
Stichworte:
S17 Electromagnetic Shielding Protection Heat Shrink Tube
Introduction
Designed for shielding and protecting electromagnetic signal interference sensitive components in military equipment.

Features
Operating temperature: -55 to 135°C
Minimum full recovery temperature: 135°C
Shrink ratio: 2:1 & 3:1
Compliant Standard GB/T 32511-2016 & GJB 8820-2015
Electromagnetic shielding, Flame-retardant
Dimension
Part No.
S17
As supplied(mm) After recovered(mm) Standard
Length
  (m)
Inner diameter
D(min.)
Inner diameter
    d(max.)
Wall thickness
      t
Shrink Ratio 2:1
3.2/1.6 3.2  1.6    0.40±0.10 0.5 
4.8/2.4 4.8  2.4    0.51±0.10 0.5 
6.4/3.2 6.4  3.2    0.64±0.12 0.5 
7.9/4.0 7.9  4.0    0.64±0.12 0.5 
9.5/4.8 9.5  4.8    0.64±0.12 0.5 
12.7/6.4 12.7  6.4    0.64±0.12 0.5 
15.9/7.9 15.9  7.9    0.64±0.12 0.5 
19.1/9.5 19.1  9.5    0.76±0.12 0.5 
22.2/11.1 22.2  11.1    0.89±0.15 0.5/1
25.4/12.7 25.4  12.7    0.89±0.15 0.5/1
31.8/15.9 31.8  15.9    1.02±0.20 0.5/1
38.1/19.1 38.1  19.1    1.02±0.20 0.5/1
50.8/25.4 50.8  25.4    1.14±0.20 0.5/1
76.2/38.1 76.2  38.1    1.27±0.20 0.5/1
101.6/50.8 101.6  50.8    1.40±0.25 0.5/1
127.0/63.5 127.0  63.5    1.52±0.25 0.5/1
Shrink Ratio 3:1
3-1 3  1    0.55±0.12 0.5 
6-2 6  2    0.65±0.12 0.5 
9-3 9  3    0.80±0.15 0.5 
12-4 12  4    0.85±0.15 0.5 
18-6 18  6    1.00±0.15 0.5 
24-8 24  8    1.20±0.20 0.5/1
39/13 39  13    1.50±0.25 0.5/1

 

Technical Data

Property Test Method Requirement
Longitudinal change -- -10%~5%
Restricted Shrinkage 175°C/30min No cracking
Water absorption 23°C/24h ≤0.5%
Tensile Strength 500mm/min ≥10.4MPa
Ultimate Elongation 500mm/min ≥200%
Heat shock 250°C/4h No cracking, dripping or flowing
Heat Aging
Tensile Strength
Ultimate Elongation
175°C/168h
Not less than 70% value before test
≥100%
Dielectric strength -- ≥7.9kV/mm
Dielectric withstand AC 2500V, 60s No breakdown
Volume resistivity -- ≥1.0×1012Ω·cm
Electromagnetic Shielding Effectiveness GBT 32511-2016
GJB 8820-2015
30MHZ~230MHz,  ≥60dB
230MHz~1GHz,  ≥50dB
1GHz~18GHz,   ≥40dB
Shielding Layer Volume Resistivity GBT 32511-2016 ≤1.0×10-1Ω·cm
Shielding Layer surface resistivity GBT 32511-2016 ≤1.0×101Ω·m2
Shielding Layer surface resistance -- ≤1Ω/10cm
Fluid resistance
Tensile Strength
Dielectric strength
23°C/24h
Not less than 70% value before test
≥100%
Flammability (colors only) -- 60 second maximum burning duration
Copper corrosion 175°C/16h No Corrosion
Low-temperature flexibility -55°C/4h No Cracking
Thermal cycling
Tensile Strength
Ultimate Elongation
-55°C/135°C/10 cycles
Not less than 70% value before test
≥ 100%
Salt spray test
Tensile Strength
Ultimate Elongation
GJB 150.11
Not less than 70% value before test
≥ 100%
Damp-heat test
Tensile Strength
Ultimate Elongation
GJB 150.9
Not less than 70% value before test
≥ 100%
Fungus Resistance GJB 150.10 No worse than rating 1